| Name |
Description |
|
Comments
|
Gets the list of associated comments.
|
|
CoordinateSystem
|
Gets or sets the CoordinateSystem.
|
|
DataModelObjectCategory
|
Gets the name of the current DataModelObject's category.
|
|
DefineBy
|
Gets or sets the DefineBy.
|
|
Direction
|
Gets or sets the Direction.
|
|
Figures
|
Gets the list of associated figures.
|
|
GraphControlsXAxis
|
Gets or sets the GraphControlsXAxis.
|
|
Images
|
Gets the list of associated images.
|
|
IndependentVariable
|
Gets or sets the IndependentVariable.
|
|
InternalObject
|
Gets the internal object. For advanced usage only.
|
|
LoadVectorAssignment
|
Gets or sets whether the LoadVectorAssignment is LoadVectorAssignment_ProgramControlled or LoadVectorAssignment_Manual.
Default: LoadVectorAssignment_ProgramControlled.
|
|
LoadVectorNumber
|
Gets or sets the load vector number for the real part of the line pressure.
When Load Vector Assignment is set to Manual, the default value of '0' represents an invalid value that must be changed to a positive integer.
|
|
LoadVectorNumberImaginary
|
Gets or sets the load vector number for the imaginary part of the line pressure.
When Load Vector Assignment is set to Manual, the default value of '0' represents an invalid value that must be changed to a positive integer.
|
|
LoadVectorNumberX
|
Gets or sets the load vector number for the real part of the line pressure in the X direction.
When Load Vector Assignment is set to Manual, the default value of '0' represents an invalid value that must be changed to a positive integer.
|
|
LoadVectorNumberXImaginary
|
Gets or sets the load vector number for the imaginary part of the line pressure in the X direction.
When Load Vector Assignment is set to Manual, the default value of '0' represents an invalid value that must be changed to a positive integer.
|
|
LoadVectorNumberY
|
Gets or sets the load vector number for the real part of the line pressure in the Y direction.
When Load Vector Assignment is set to Manual, the default value of '0' represents an invalid value that must be changed to a positive integer.
|
|
LoadVectorNumberYImaginary
|
Gets or sets the load vector number for the imaginary part of the line pressure in the Y direction.
When Load Vector Assignment is set to Manual, the default value of '0' represents an invalid value that must be changed to a positive integer.
|
|
LoadVectorNumberZ
|
Gets or sets the load vector number for the real part of the line pressure in the Z direction.
When Load Vector Assignment is set to Manual, the default value of '0' represents an invalid value that must be changed to a positive integer.
|
|
LoadVectorNumberZImaginary
|
Gets or sets the load vector number for the imaginary part of the line pressure in the Z direction.
When Load Vector Assignment is set to Manual, the default value of '0' represents an invalid value that must be changed to a positive integer.
|
|
Location
|
Gets or sets the Location.
|
|
Magnitude
|
Gets the Magnitude.
|
|
MagnitudeImag
|
Returns the Field to get or set the value of the Magnitude – Imag property. Default: [0 [N m^-1]].
|
|
Name
|
Gets the name of the object.
|
|
NumberOfSegments
|
Gets or sets the NumberOfSegments.
|
|
ObjectId
|
Gets the internal id of the object.
|
|
ObjectTags
|
Gets an IEnumerable object of the tags that 'this' is a part of.
|
|
Parent
|
Gets the parent object.
|
|
PhaseAngle
|
Gets or sets the PhaseAngle.
|
|
Properties
|
Gets the list of properties for this object.
|
|
RangeMaximum
|
Gets or sets the RangeMaximum.
|
|
RangeMinimum
|
Gets or sets the RangeMinimum.
|
|
ReadOnly
|
Gets or sets the ReadOnly.
|
|
RpmSelection
|
Gets or sets the RPM value at which the load is applied.
An exception is thrown if MultiStep is not True, StepVarying is not Yes, or HarmonicMultiStepType is not RPM.
|
|
SharedRefBody
|
Gets or sets the SharedRefBody.
|
|
StepSelectionRepresentation
|
Gets or sets the string representation of the step numbers at which the load is applied.
An exception is thrown if any of the below conditions are met:
1. MultiStep is not True.
2. StepVarying is not Yes.
3. HarmonicMultiStepType is not Load_Step.
4. The input format is invalid.
|
|
StepVarying
|
Gets or sets whether the load is applied to a specific RPM/step number. Default: No.
An exception is thrown if is not True.
|
|
Suppressed
|
Gets or sets the Suppressed.
|
|
VisibleProperties
|
Gets the list of properties that are visible for this object.
|
|
XComponent
|
Gets the XComponent.
|
|
XComponentImag
|
Returns the Field to get or set the value of the X Component – Imag property. Default: [0 [N m^-1]].
|
|
XYZFunctionCoordinateSystem
|
Gets or sets the XYZFunctionCoordinateSystem.
|
|
YComponent
|
Gets the YComponent.
|
|
YComponentImag
|
Returns the Field to get or set the value of the Y Component – Imag property. Default: [0 [N m^-1]].
|
|
ZComponent
|
Gets the ZComponent.
|
|
ZComponentImag
|
Returns the Field to get or set the value of the Z Component – Imag property. Default: [0 [N m^-1]].
|